Queensland Police Service

Site

Calibration Laboratory – Chemical Metrology

Accreditation No.

19481

Site No.

22417

Date of Accreditation

01 Jul 2014

Address

20 Pickering Street
Alderley, QLD 4051
Australia

police.qld.gov.au

Contact

Mr Kostas Iliakopoulos P: +61 (07) 35535221

Availability

Services conditionally available to external clients

Scope of Accreditation

Calibration Laboratory – Chemical Metrology

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Chemical metrology - Breath alcohol instruments Lion Intoxylizer 8000 Alcohol content Direct measurement against a reference standard

In-house methods 

Queensland Police Service

procedures

BA-2-07 and BA-2-08

0.000 to 0.500 g/210L alcohol content

Capability

With Calibration and Measurement Capability of -
0.0037 g/210L for above 0.000 up to 0.050 g/210L
0.0045 g/210L for above 0.050 up to 0.100 g/210L
 4.36% for above 0.100 up to 0.500 g/210L

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.